Shop with Confidence — Free Shipping on All Orders

{"id":8347055718551,"title":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868)","handle":"non-contact-thermometer-analog-dt-103-iris-ohyama-dt-103pc868","description":"\u003ch2\u003e Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) \u003c\/h2\u003e\u003cp\u003e \u003cspan\u003e[Please be sure to refer to the instruction manual]\u003cbr\u003e\u003cbr\u003e[ Common name]\u003cbr\u003eSkin infrared thermometer\u003cbr\u003e\u003cbr\u003e[Product name] \u003cbr\u003ePick thermometer DT-103\u003cbr\u003e\u003cbr\u003e[Contraindications\/prohibited]\u003cbr\u003e・Self-diagnosis of temperature measurement results Do not treat or treat. \u003cbr\u003e [This may cause symptoms to worsen. ]\u003cbr\u003e・Please keep out of reach of infants. Also, please avoid using it only with children. \u003cbr\u003e [This may result in suffocation or injury. ]\u003cbr\u003e・Do not use the product under conditions that do not meet the usage conditions specified in the Precautions for Use, and do not repair, modify, or readjust it by anyone other than the manufacturer. \u003cbr\u003e The manufacturer is not responsible for any damage caused by these. \u003cbr\u003e\u003cbr\u003e[Item specifications, etc.]\u003cbr\u003eMeasurement mode: Body temperature measurement mode and object surface temperature measurement mode\u003cbr\u003ePower supply: DC3V\u003cbr\u003eMeasurement range Biometric measurement mode (forehead): +32.0~+42.9 ℃\u003cbr\u003eObject measurement mode (object surface): 0~100℃\u003cbr\u003eBody temperature measurement accuracy: +35.5~42.0℃, within ±0.2℃\u003cbr\u003eOther than that, within ±0.3℃\u003cbr\u003eBody temperature display: 3-digit +℃ display (every 0.1℃)\u003cbr\u003eUsing environment temperature: 10~40℃\u003cbr\u003eUsing environment humidity: 15~85%RH\u003cbr\u003eStorage environment temperature and humidity: -20~+50℃, 95% Below RH (no condensation)\u003cbr\u003e\u003cbr\u003e[Precautions for use]\u003cbr\u003e\u0026lt;Important basic precautions\u0026gt;\u003cbr\u003e・Do not measure body temperature anywhere other than the forehead. \u003cbr\u003e・After exercising or bathing, wait at least 30 minutes before taking your temperature. \u003cbr\u003e・If there is a temperature difference between the place where this product is stored and the place where you will be measuring, please leave it in the place where you will use it for at least 30 minutes before taking the measurement. \u003cbr\u003e・If your forehead is cold, wait until it warms up before measuring. \u003cbr\u003e・When the battery level mark is displayed, please replace the battery. \u003cbr\u003e・Please note that the correct temperature may not be displayed in the following cases. \u003cbr\u003e - If the patient has an injury to the forehead, do not measure the forehead temperature. \u003cbr\u003e Areas of tissue damaged by scar tissue or skin diseases will sense body temperature, so do not measure areas of tissue damaged by scar tissue or skin diseases. \u003cbr\u003e ・When measuring in a place exposed to wind such as near an air conditioner\u003cbr\u003e ・When direct sunlight is hitting the forehead\u003cbr\u003e ・When the forehead is wet from swimming, bathing, showering, sweating, etc.\u003cbr\u003e ・Immediately after exercise\u003cbr\u003e ・If you were in a place with a temperature different from the place to be measured until just before taking the measurement\u003cbr\u003e ・If the body was in a place with a temperature different from the place to be measured until just before taking the measurement\u003cbr\u003e・If there is something between the forehead and the sensor that interferes with the measurement, such as hair or foundation. ・If there is another part of the body, such as a hand, near the measurement area (forehead). ・If the IR sensor Please do not hurt it. \u003cbr\u003e・Do not immerse the main unit in water. \u003cbr\u003e・Please use within the ambient temperature range of 10 to 40 degrees Celsius. \u003cbr\u003e・To ensure the accuracy of measurement data, do not measure temperature in environments with strong electromagnetic interference (such as operating environments of microwave and high frequency equipment). \u003cbr\u003e\u003cbr\u003e[Name of manufacturer and manufacturer]\u003cbr\u003eManufacturer: ICST Co., Ltd.\u003cbr\u003e S-4 Tower, 5-17-1 Kamiochiai, Chuo-ku, Saitama City, Saitama Prefecture\u003cbr\u003e \u0026gt;Telephone number: 048-857-8026\u003cbr\u003eForeign manufacturer: Shenzhen Pacom Medical Instruments Co., Ltd.\u003cbr\u003eCountry name: People's Republic of China\u003cbr\u003e\u003cbr\u003e[Purpose of use or effect\/efficacy]\u003cbr\u003e This product is used to measure the temperature of the skin on the body surface. \u003c\/span\u003e \u003c\/p\u003e\u003cul class=\"a-unordered-list a-vertical a-spacing-mini\"\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item \"\u003e Medical device classification: Specified controlled medical device \u003c\/span\u003e\u003c\/li\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e Medical device certification number: 302AGBZX00102000 span\u0026gt;\u003c\/span\u003e\u003c\/li\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e Product size (cm): Width approx. 4.5 x Depth approx. 9.5 x Height approx. 14.9\/Weight :Approx. 114g (not including battery) \u003c\/span\u003e\u003c\/li\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e Country of origin: China \u003c\/span\u003e\u003c\/li\u003e li\u0026gt; \u003c\/ul\u003e","published_at":"2024-04-26T03:08:40+10:00","created_at":"2024-04-26T03:08:49+10:00","vendor":"IRIS OHYAMA","type":"Health Beauty","tags":["healthJAPAN_March2024"],"price":16500,"price_min":16500,"price_max":16500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44129260109975,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"jp-B08P77TQ9V","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868)","public_title":null,"options":["Default Title"],"price":16500,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/newnestshop.com\/cdn\/shop\/files\/jp-B08P77TQ9V.jpg?v=1714088788","\/\/newnestshop.com\/cdn\/shop\/files\/614jkoI_XCL._AC_SX679.jpg?v=1714064929","\/\/newnestshop.com\/cdn\/shop\/files\/61s51EmmciL._AC_SX679.jpg?v=1714064929","\/\/newnestshop.com\/cdn\/shop\/files\/61Ad2Rnl5NL._AC_SX679.jpg?v=1714064929","\/\/newnestshop.com\/cdn\/shop\/files\/617hW9GReIL._AC_SX679.jpg?v=1714064929","\/\/newnestshop.com\/cdn\/shop\/files\/61vRED1_ACL._AC_SX679.jpg?v=1714064929"],"featured_image":"\/\/newnestshop.com\/cdn\/shop\/files\/jp-B08P77TQ9V.jpg?v=1714088788","options":["Title"],"media":[{"alt":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) - NewNest Australia","id":34244697882775,"position":1,"preview_image":{"aspect_ratio":0.522,"height":887,"width":463,"src":"\/\/newnestshop.com\/cdn\/shop\/files\/jp-B08P77TQ9V.jpg?v=1714088788"},"aspect_ratio":0.522,"height":887,"media_type":"image","src":"\/\/newnestshop.com\/cdn\/shop\/files\/jp-B08P77TQ9V.jpg?v=1714088788","width":463},{"alt":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) - NewNest Australia","id":34242397012119,"position":2,"preview_image":{"aspect_ratio":1.0,"height":679,"width":679,"src":"\/\/newnestshop.com\/cdn\/shop\/files\/614jkoI_XCL._AC_SX679.jpg?v=1714064929"},"aspect_ratio":1.0,"height":679,"media_type":"image","src":"\/\/newnestshop.com\/cdn\/shop\/files\/614jkoI_XCL._AC_SX679.jpg?v=1714064929","width":679},{"alt":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) - NewNest Australia","id":34242397044887,"position":3,"preview_image":{"aspect_ratio":1.0,"height":679,"width":679,"src":"\/\/newnestshop.com\/cdn\/shop\/files\/61s51EmmciL._AC_SX679.jpg?v=1714064929"},"aspect_ratio":1.0,"height":679,"media_type":"image","src":"\/\/newnestshop.com\/cdn\/shop\/files\/61s51EmmciL._AC_SX679.jpg?v=1714064929","width":679},{"alt":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) - NewNest Australia","id":34242397077655,"position":4,"preview_image":{"aspect_ratio":0.926,"height":733,"width":679,"src":"\/\/newnestshop.com\/cdn\/shop\/files\/61Ad2Rnl5NL._AC_SX679.jpg?v=1714064929"},"aspect_ratio":0.926,"height":733,"media_type":"image","src":"\/\/newnestshop.com\/cdn\/shop\/files\/61Ad2Rnl5NL._AC_SX679.jpg?v=1714064929","width":679},{"alt":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) - NewNest Australia","id":34242397110423,"position":5,"preview_image":{"aspect_ratio":0.981,"height":692,"width":679,"src":"\/\/newnestshop.com\/cdn\/shop\/files\/617hW9GReIL._AC_SX679.jpg?v=1714064929"},"aspect_ratio":0.981,"height":692,"media_type":"image","src":"\/\/newnestshop.com\/cdn\/shop\/files\/617hW9GReIL._AC_SX679.jpg?v=1714064929","width":679},{"alt":"Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) - NewNest Australia","id":34242397143191,"position":6,"preview_image":{"aspect_ratio":1.0,"height":679,"width":679,"src":"\/\/newnestshop.com\/cdn\/shop\/files\/61vRED1_ACL._AC_SX679.jpg?v=1714064929"},"aspect_ratio":1.0,"height":679,"media_type":"image","src":"\/\/newnestshop.com\/cdn\/shop\/files\/61vRED1_ACL._AC_SX679.jpg?v=1714064929","width":679}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003e Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868) \u003c\/h2\u003e\u003cp\u003e \u003cspan\u003e[Please be sure to refer to the instruction manual]\u003cbr\u003e\u003cbr\u003e[ Common name]\u003cbr\u003eSkin infrared thermometer\u003cbr\u003e\u003cbr\u003e[Product name] \u003cbr\u003ePick thermometer DT-103\u003cbr\u003e\u003cbr\u003e[Contraindications\/prohibited]\u003cbr\u003e・Self-diagnosis of temperature measurement results Do not treat or treat. \u003cbr\u003e [This may cause symptoms to worsen. ]\u003cbr\u003e・Please keep out of reach of infants. Also, please avoid using it only with children. \u003cbr\u003e [This may result in suffocation or injury. ]\u003cbr\u003e・Do not use the product under conditions that do not meet the usage conditions specified in the Precautions for Use, and do not repair, modify, or readjust it by anyone other than the manufacturer. \u003cbr\u003e The manufacturer is not responsible for any damage caused by these. \u003cbr\u003e\u003cbr\u003e[Item specifications, etc.]\u003cbr\u003eMeasurement mode: Body temperature measurement mode and object surface temperature measurement mode\u003cbr\u003ePower supply: DC3V\u003cbr\u003eMeasurement range Biometric measurement mode (forehead): +32.0~+42.9 ℃\u003cbr\u003eObject measurement mode (object surface): 0~100℃\u003cbr\u003eBody temperature measurement accuracy: +35.5~42.0℃, within ±0.2℃\u003cbr\u003eOther than that, within ±0.3℃\u003cbr\u003eBody temperature display: 3-digit +℃ display (every 0.1℃)\u003cbr\u003eUsing environment temperature: 10~40℃\u003cbr\u003eUsing environment humidity: 15~85%RH\u003cbr\u003eStorage environment temperature and humidity: -20~+50℃, 95% Below RH (no condensation)\u003cbr\u003e\u003cbr\u003e[Precautions for use]\u003cbr\u003e\u0026lt;Important basic precautions\u0026gt;\u003cbr\u003e・Do not measure body temperature anywhere other than the forehead. \u003cbr\u003e・After exercising or bathing, wait at least 30 minutes before taking your temperature. \u003cbr\u003e・If there is a temperature difference between the place where this product is stored and the place where you will be measuring, please leave it in the place where you will use it for at least 30 minutes before taking the measurement. \u003cbr\u003e・If your forehead is cold, wait until it warms up before measuring. \u003cbr\u003e・When the battery level mark is displayed, please replace the battery. \u003cbr\u003e・Please note that the correct temperature may not be displayed in the following cases. \u003cbr\u003e - If the patient has an injury to the forehead, do not measure the forehead temperature. \u003cbr\u003e Areas of tissue damaged by scar tissue or skin diseases will sense body temperature, so do not measure areas of tissue damaged by scar tissue or skin diseases. \u003cbr\u003e ・When measuring in a place exposed to wind such as near an air conditioner\u003cbr\u003e ・When direct sunlight is hitting the forehead\u003cbr\u003e ・When the forehead is wet from swimming, bathing, showering, sweating, etc.\u003cbr\u003e ・Immediately after exercise\u003cbr\u003e ・If you were in a place with a temperature different from the place to be measured until just before taking the measurement\u003cbr\u003e ・If the body was in a place with a temperature different from the place to be measured until just before taking the measurement\u003cbr\u003e・If there is something between the forehead and the sensor that interferes with the measurement, such as hair or foundation. ・If there is another part of the body, such as a hand, near the measurement area (forehead). ・If the IR sensor Please do not hurt it. \u003cbr\u003e・Do not immerse the main unit in water. \u003cbr\u003e・Please use within the ambient temperature range of 10 to 40 degrees Celsius. \u003cbr\u003e・To ensure the accuracy of measurement data, do not measure temperature in environments with strong electromagnetic interference (such as operating environments of microwave and high frequency equipment). \u003cbr\u003e\u003cbr\u003e[Name of manufacturer and manufacturer]\u003cbr\u003eManufacturer: ICST Co., Ltd.\u003cbr\u003e S-4 Tower, 5-17-1 Kamiochiai, Chuo-ku, Saitama City, Saitama Prefecture\u003cbr\u003e \u0026gt;Telephone number: 048-857-8026\u003cbr\u003eForeign manufacturer: Shenzhen Pacom Medical Instruments Co., Ltd.\u003cbr\u003eCountry name: People's Republic of China\u003cbr\u003e\u003cbr\u003e[Purpose of use or effect\/efficacy]\u003cbr\u003e This product is used to measure the temperature of the skin on the body surface. \u003c\/span\u003e \u003c\/p\u003e\u003cul class=\"a-unordered-list a-vertical a-spacing-mini\"\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item \"\u003e Medical device classification: Specified controlled medical device \u003c\/span\u003e\u003c\/li\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e Medical device certification number: 302AGBZX00102000 span\u0026gt;\u003c\/span\u003e\u003c\/li\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e Product size (cm): Width approx. 4.5 x Depth approx. 9.5 x Height approx. 14.9\/Weight :Approx. 114g (not including battery) \u003c\/span\u003e\u003c\/li\u003e \u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003e Country of origin: China \u003c\/span\u003e\u003c\/li\u003e li\u0026gt; \u003c\/ul\u003e"}

Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868)

In Stock. Leaves warehouse within 2 - 3 business days

$165.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Non-contact thermometer analog DT-103 IRIS OHYAMA DT-103(PC868)

[Please be sure to refer to the instruction manual]

[ Common name]
Skin infrared thermometer

[Product name]
Pick thermometer DT-103

[Contraindications/prohibited]
・Self-diagnosis of temperature measurement results Do not treat or treat.
[This may cause symptoms to worsen. ]
・Please keep out of reach of infants. Also, please avoid using it only with children.
[This may result in suffocation or injury. ]
・Do not use the product under conditions that do not meet the usage conditions specified in the Precautions for Use, and do not repair, modify, or readjust it by anyone other than the manufacturer.
The manufacturer is not responsible for any damage caused by these.

[Item specifications, etc.]
Measurement mode: Body temperature measurement mode and object surface temperature measurement mode
Power supply: DC3V
Measurement range Biometric measurement mode (forehead): +32.0~+42.9 ℃
Object measurement mode (object surface): 0~100℃
Body temperature measurement accuracy: +35.5~42.0℃, within ±0.2℃
Other than that, within ±0.3℃
Body temperature display: 3-digit +℃ display (every 0.1℃)
Using environment temperature: 10~40℃
Using environment humidity: 15~85%RH
Storage environment temperature and humidity: -20~+50℃, 95% Below RH (no condensation)

[Precautions for use]
<Important basic precautions>
・Do not measure body temperature anywhere other than the forehead.
・After exercising or bathing, wait at least 30 minutes before taking your temperature.
・If there is a temperature difference between the place where this product is stored and the place where you will be measuring, please leave it in the place where you will use it for at least 30 minutes before taking the measurement.
・If your forehead is cold, wait until it warms up before measuring.
・When the battery level mark is displayed, please replace the battery.
・Please note that the correct temperature may not be displayed in the following cases.
- If the patient has an injury to the forehead, do not measure the forehead temperature.
Areas of tissue damaged by scar tissue or skin diseases will sense body temperature, so do not measure areas of tissue damaged by scar tissue or skin diseases.
・When measuring in a place exposed to wind such as near an air conditioner
・When direct sunlight is hitting the forehead
・When the forehead is wet from swimming, bathing, showering, sweating, etc.
・Immediately after exercise
・If you were in a place with a temperature different from the place to be measured until just before taking the measurement
・If the body was in a place with a temperature different from the place to be measured until just before taking the measurement
・If there is something between the forehead and the sensor that interferes with the measurement, such as hair or foundation. ・If there is another part of the body, such as a hand, near the measurement area (forehead). ・If the IR sensor Please do not hurt it.
・Do not immerse the main unit in water.
・Please use within the ambient temperature range of 10 to 40 degrees Celsius.
・To ensure the accuracy of measurement data, do not measure temperature in environments with strong electromagnetic interference (such as operating environments of microwave and high frequency equipment).

[Name of manufacturer and manufacturer]
Manufacturer: ICST Co., Ltd.
S-4 Tower, 5-17-1 Kamiochiai, Chuo-ku, Saitama City, Saitama Prefecture
>Telephone number: 048-857-8026
Foreign manufacturer: Shenzhen Pacom Medical Instruments Co., Ltd.
Country name: People's Republic of China

[Purpose of use or effect/efficacy]
This product is used to measure the temperature of the skin on the body surface.

  • Medical device classification: Specified controlled medical device
  • Medical device certification number: 302AGBZX00102000 span>
  • Product size (cm): Width approx. 4.5 x Depth approx. 9.5 x Height approx. 14.9/Weight :Approx. 114g (not including battery)
  • Country of origin: China
  • li>

Buy with confidence as this product comes with 18 months full local warranty in Australia & New Zealand (unless otherwise stated in the overview).

This product also comes with the benefits of the CocoonPower Warranty. For further details please read our Warranty Guidelines.

You can also purchase 3 Year Extended Care. If you are interested please see our Extended Care Information.